Electric lighting of machinery – control checklist
Initial inspection
No |
Control question |
YES |
NO |
Comments |
1. |
Is the machine equipped with a local lighting fixture? |
|
|
|
2. |
Is the local lighting fixture integrated with the machine or is it separate? |
|
|
|
3. |
Is the light emitted by the applied local lighting fixture compliant with the standards in the working area of the machine where visual labour is performed? |
|
|
Light intensity and uniformity determination required |
4. |
Is the colour rendering index (Ra) for the light source used in the fixture compliant with standard requirements? |
|
|
Required reading from the source of this parameter |
5. |
Is the colour of the light emitted by the source used in the fixture warm (2700 – 4000 K) |
|
|
Required reading from the source of this parameter |
6. |
Does the applied local lighting fixture cause direct glare (light source points at the eyes of the employee)? |
|
|
|
7. |
Do the glossy construction elements of the machine cause reflection glare for the employee? |
|
|
|
8. |
Does the design of the machine and/or guards prevent the access of local lighting to all required work areas? |
|
|
|
9. |
Does the local lighting fixture provide good lighting of areas where regulations, adjustments and frequent maintenance are performed? |
|
|
|
10. |
Does the location of the local lighting source cause the creation of dangerous shadows in the area of the machine? |
|
|
|
11. |
Can the stroboscopic effect occur during the operation of the local lighting source? |
|
|
|
12. |
Does the local lighting source cause the stroboscopic effect? |
|
|
Inspection of the type of starting systems in the case of discharge light sources (fluorescent lamps) |
13. |
Is light flashing or pulsation visible? |
|
|
Inspection of the technical condition of the starting system and light source |
14. |
Is the position of the fixture element containing the light source adjustable? |
|
|
|
15. |
Is the adjustment of the position of the fixture element containing the light source easy – does not require tools? |
|
|
|
16. |
Is the adjustment of the position of the fixture element containing the light source safe – does not create risk for the adjusting personnel (burning with hot lamp bowl, scratching, etc.)? |
|
|
|
17. |
Is the electrical supply of the lighting fixture provided as safe for the user? |
|
|
|
18. |
Is switching on of the lighting fixture safe for the user? |
|
|
|
No |
Control question |
YES |
NO |
Comments |
1. |
Is the machine equipped with a local lighting fixture? |
|
|
|
2. |
Is the local lighting fixture integrated with the machine or is it separate? |
|
|
|
3. |
Is additional lighting required for any work areas of the machine? |
|
|
|
4. |
Does the local lighting fixture provide good lighting of the working area of the machine where visual labour is performed? |
|
|
|
5. |
Does the local lighting fixture provide good lighting of areas where regulations, adjustments and frequent maintenance are performed? |
|
|
|
6. |
Is lighting of the working area of the machine where visual labour is performed sufficient? |
|
|
Light intensity and uniformity determination required |
7. |
Does the applied local lighting fixture cause direct glare (light source points at the eyes of the employee)? |
|
|
|
8. |
Do the glossy construction elements of the machine cause reflection glare for the employee? |
|
|
|
9. |
Does the design of the machine and/or guards prevent the access of local lighting to all required work areas? |
|
|
|
10. |
Does the location of the local lighting source cause the creation of dangerous shadows in the area of the machine? |
|
|
|
11. |
Do the light sources used in the local lighting fixture cause colour distortions of observed details? |
|
|
Required reading from the source of this parameter |
12. |
Is the colour of the light emitted by the source used in the fixture pleasant? |
|
|
Required reading from the source of this parameter |
13. |
Is light flashing or pulsation visible? |
|
|
Inspection of the technical condition of the starting system and light source |
14. |
Can the stroboscopic effect occur during the operation of the local lighting source? |
|
|
|
15. |
Does the local lighting source cause the stroboscopic effect? |
|
|
Inspection of the type of starting systems in the case of discharge light sources (fluorescent lamps) |
16. |
Is the position of the fixture element containing the light source adjustable? |
|
|
|
17. |
Is the adjustment of the position of the fixture element containing the light source easy – does not require tools? |
|
|
|
18. |
Is the adjustment of the position of the fixture element containing the light source safe – does not create risk for the adjusting personnel (burning with hot lamp bowl, scratching, etc.)? |
|
|
|
19. |
Is the electrical supply of the lighting fixture provided as safe for the user? |
|
|
|
20. |
Is switching on of the lighting fixture safe for the user? |
|
|
|
No |
Control question |
YES |
NO |
Comments |
19. |
Is the machine equipped with a local lighting fixture? |
|
|
|
20. |
Is the local lighting fixture integrated with the machine or is it separate? |
|
|
|
21. |
Does the local lighting fixture provide good lighting of the working area of the machine where visual labour is performed? |
|
|
|
22. |
Does the local lighting fixture provide good lighting of areas where regulations, adjustments and frequent maintenance are performed? |
|
|
|
23. |
Is lighting of the working area of the machine where visual labour is performed sufficient? |
|
|
Light intensity and uniformity determination required |
24. |
Does the applied local lighting fixture cause direct glare (light source points at the eyes of the employee)? |
|
|
|
25. |
Do the glossy construction elements of the machine cause reflection glare for the employee? |
|
|
|
26. |
Does the design of the machine and/or guards prevent the access of local lighting to all required work areas? |
|
|
|
27. |
Does the location of the local lighting source cause the creation of dangerous shadows in the area of the machine? |
|
|
|
28. |
Is the colour rendering index (Ra) for the light source used in the fixture compliant with standard requirements? |
|
|
Required reading from the source of this parameter |
29. |
Is the colour of the light emitted by the source used in the fixture warm (2700 – 4000 K) |
|
|
Required reading from the source of this parameter |
30. |
Is light flashing or pulsation visible? |
|
|
Inspection of the technical condition of the starting system and light source |
31. |
Can the stroboscopic effect occur during the operation of the local lighting source? |
|
|
|
32. |
Does the local lighting source cause the stroboscopic effect? |
|
|
Inspection of the type of starting systems in the case of discharge light sources (fluorescent lamps) |
33. |
Is the position of the fixture element containing the light source adjustable? |
|
|
|
34. |
Is the adjustment of the position of the fixture element containing the light source easy – does not require tools? |
|
|
|
35. |
Is the adjustment of the position of the fixture element containing the light source safe – does not create risk for the adjusting personnel (burning with hot lamp bowl, scratching, etc.)? |
|
|
|
36. |
Is the electrical supply of the lighting fixture provided as safe for the user? |
|
|
|
37. |
Is switching on of the lighting fixture safe for the user? |
|
|
|